Total Comfort - Newmac ~ Quiet, Clean, High Efficiency Heating Solutions


The Patented Newmac Balanced Flue Sealed Vent System (SVS) is the latest technology for venting of Newmac appliances.

System features:

  • Combined single wall terminal for both burner combustion air and flue exhaust gases
  • All stainless steel construction
  • Zero clearance to combustibles for terminal installation
  • Serviceable seals permit vent cleaning and inspection as codes require
  • Exceptionally quiet operation
  • Multi fire range of 0.5 - 1.50 U.S.G.P.H. - designed for Newmac appliances
  • Flue gases jetted away from building exterior
  • Pre-heated combustion air
  • Superior wind performance
  • Positive blockage safety sensor
  • Reduced standby losses in boilers
  • No moving parts to maintain
  • Truly sealed system - no vacuum relief valve required
  • System uses a pre and post purge burner cycle for complete flue gas removal
  • Safety certified by CSA



Click here for SVS Flex Vent Assembly Instructions


Specifications

SVS Burner Approvals: Designed for sealed combustion

Terminal Specifications

Through the wall hole opening 7 in. x 7 in.
Siding recess for head 12 1/4 in. x 12 1/4
Max siding recess depth 1 in.
Max wall thickness (excluding siding) 10 in.
Max height from appliance 10 ft.
Min height from appliance breech 0

Oil Flex Vent Pipe

Maximum vent length 20 ft
Minimum vent length –
Minimum inside bend radius 1 ft.
Support spacing 3 ft.
Minimum gradient 1/4 in./ft. toward appliance breach


1 Servicable Connections
2 SVS Terminal
3 Combustion Air
4 Flexible Flue Pipe
5 Blockage Control